● Stainless Steel housing and metal core enables a grounded construction preventing spark generation
● All wiring shielded with conductive, grounded, PTFE conduit preventing spark generation
● Low flow N2 housing purge provides positive pressure inert environment preventing the possibility of flame or ignition
● Indirect heating, no immersed heater elements which can lead to shock or contamination
● Class I, Division II Environment Compliant (Third Party Certified)
● Continuous internal flow path, no O-Rings or compression seals
● All wetted surfaces are high purity PFA
● Stainless Steel housing
● Maximized watt density for performance
● Zero maintenance required
● PFA fluid path, wide solvent compatibility
● Redundant Over-Temperature Devices
Available Wattages: 1.5Kw to 12.0Kw
Process Chemistries: IPA (Isopropyl alcohol), EKC (EKC265, EKC830, EKC270), Acetone, Ethanol, Toluene, MEK (methyl ethyl ketone), NMP, and much more.
Max. Operating Temp: 80 °C
Max. Pressure: 40psi @ 80 °C
Voltages: 200 to 400VAC, single or 3 phase, model dependent
Meets Requirments of: Semi S2 & S3
Equipment Marking:
II 3G Ex pzc IIC T2 Gc
Ex pzc IIC T2
IECEx ETL 19.0027U ITS19ATEX104872U
Certified to:
IECEx Standards: IEC 60079-0:2017, IEC 60079-2:2014, IEC 61010-1, IEC 61010-2-10, UL 499 & CSA 22.2 No.88
ATEX Standards: EN 60079-0:2018, EN 60079-2:2014/AC:2015
USA/CAN Standards: NFPA 496:2016 Ed.2017, UL 60079-0:2019 Ed.7, UL 60079-2:2017 Ed.6, CSA C22.2 No. 60079-0:2019 Ed.4, CSA C22.2 No. 60079-2:2016 Ed.2
USA – Class 1, Division 2, Group A, B, C, AND D, Type Z; T2
Class 1, Zone 2, Aex pzc IIc T2 Gc
CAN – Ex pzc IIC T2 Gc